  Home > Product > Water Analysis > HACH > 5500 sc







HACH COMPANY was established in 1947, in Ames, Iowa, USA. For more than 60 years, Hach has been the world market leader for Analytical Instrumentation for Complete Water Analysis, providing solutions for lab, process and field.


In 2002, GLI, a leading US manufacturer of process electro-chemistry analytical instruments, became part of the Hach Company family.

Water analysis has to be right. Our customers deserve complete, reliable solutions that they can be fully  confident in. Hach is your answer. We make water analysis simpler















Phosphate Analyzer

5500 sc


Phosphate Analyzer



Details

Only two liters of reagent are required for the analyzer to perform unattended for up to 90 days; twice as long as the Series 5000. The industry's only pressurized reagent delivery system eliminates the frequent maintenance associated with pumps. Predictive diagnostic tools, including Hach's proprietary Prognosys technology, warning LEDs, and high-visibility notification screens let you avoid unplanned downtime. No more dripping reagents on the instrument, the floor, or your clothing while fumbling with tubes and straws. Simply match the color-coded cap to the sealed reagent bottle and twist gently. Grab Sample In and Grab Sample Out features allow quick analysis of a grab sample poured into the analyzer, and facilitate taking a sample out of the analyzer to verify in a lab test.

  • 90 Days of Continuous Run Time
  • Save Time on Maintenance
  • Avoid Downtime
  • Clean, Fast and Easy Reagent Change
  • Verify Easily with Hach Lab Products So You Don't Waste Time Second-guessing

Specifications

Accuracy:LR model: ±4 µg/L or ±4% of reading, whichever is greater;
HR model: ±500 µg/L or ±5% of reading, whichever is greater
Alarm:Four relays output; type: not powered SPDT relays, each rated at
5 A resistive, 240 VAC maximum
Connection: 18 to 14 AWG wire, 18 AWG stranded recommended
Certifications:CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000 )
KC (EN 61326-1: 2006)
C-tick (EN 61326-1: 2006)
cETLus (UL 61010-1: 2012; NEMA 250: 2003; CSA C22.2 No 61010-1: 2012)
Controller Compatibility:sc200, sc1000
Dimensions Metric (H x W X D):804 mm x 452 mm x 360 mm
Enclosure Rating:NEMA 4X/IP56
Fitting type:Sample line and sample bypass drain: 6 mm (¼-in.)
Air purge inlet: 6 mm (¼-in.) Chemical and case drains: 9.5 mm (3/8-in.)
Grab Sample:Grab Sample In and Grab Sample Out capability
Light Source:Class 1M LED (light emitting diode) with a peak
wavelength of 810 nm
Lower Limit of Detection (LOD):LR model: 4 µg/L
HR model: 200 µg/L
Manual Languages:English
French
Spanish
B. Portuguese
Chinese
Japanese
Korean
Thai
German
Italian
C. Portuguese
Czech
Danish
Dutch
Polish
Swedish
Finnish
Bulgarian
Hungarian
Romanian
Lithuanian
Russian
Turkish
Slovak
Slovenian
Croatian
Greek
Estonian
Measuring Principle:Colorimetric
Mounting:Wall, panel or table
Number of Channels:1
Operating Humidity:5 to 95 % non-condensing (indoor use only)
Operating Temperature Range:5 to 45 °C (41 - 113 °F)
Output:4 to 20 mA
Parameter:Low Range Phosphate
Pollution Degree:2/II
Power Requirements (Hz):50/60 Hz
Power Requirements (Voltage):100 - 240 VAC
Protection Class:I
Range:0 - 3000 µg/L as PO4
Reagent Consumption:2 L of each reagent every 90 days with 15 minute cycle time
Relays:Four; type: not powered SPDT relays, each rated at 5 A resistive, 240 VAC maximum
Repeatability:LR model: ±1%
HR model: ±500 µg/L or ±5% of reading, whichever is greater
Response Time:Typically, 9.5 minutes at 25 °C (77 °F); changes with temperature
Sample Flow Rate:55 to 300 mL/min
Sample Pressure:2 to 87 psi (to Preset Pressure Regulator)
Sample Temperature:5 to 50 °C (41 - 122 °F)
Storage Conditions:-20 to 60 °C (-4 - 140 °F)
Weight:44.09 lbs. (20 kg) without reagents and standards, 80 lbs. (36.3 kg) with reagents