Turbidimeter (High-Range)

Surface Scatter® 7 sc


Turbidimeter (High-Range)



Details


Applications: Drinking Water, Wastewater, Industrial Water.

The Surface Scatter 7 sc High Range Turbidimeter with sc200 controller offers superior performance features. It measures a turbidity range from 0 to 9999 NTU. Includes calibration cylinder, 4000 NTU Formazin, installation accessories, and instruction manual. Note: only one SS7 sc sensor can attach to one sc200 controller, if a second different sc sensor is required for this configuration please contact the Hach Company - Process Technical Group for further details.

  • Virtually maintenance-free, optics never touch the sample
  • Durable-manufactured with corrosion/heat-resistant materials for extended life
  • Wide turbidity measurement range from 0 to 9,999 NTU
  • Wide turbidity measurement range from 0 to 9,999 NTU
  • Backed by a 2-year Warranty

Specifications

Accuracy:±5% of reading or ±0.1 NTU (whichever is greater) from 0 up to 2000 NTU
Accuracy 2:± 10% of reading from 2000 to 9999 NTU
Alarm:Relays can be programmed through sc controller for warning, alarm, feeder, event, pulse width modulation, and frequency control.
Ambient Temperature:0 to 50 °C
Dimensions Metric (H x W X D):642 mm x 675 mm x 190 mm
Enclosure Construction:Plastic instrument enclosure
Enclosure Rating:NEMA 12
Installation category:Category II
Mounting:Wall mount
Power Requirements (Voltage):None
Range:0 to 9999
Range 2:Nephelometric Turbidity Units (NTU)
Relative Humidity:5 to 95 % non-condensing
Repeatability:0.1 NTU or ±0.04 NTU, whichever is greater
Resolution:0.01 NTU up to 999.99 NTU
0.1 NTU between 1000 to 9999.9 NTU
Response Time:Initial response in 45 seconds
Sample Flow Rate:Sample flow required 1.0 to 2.0 L/min (15 to 30 gal/hr)
Sample Input:0.75 inch NPT female thread
Sample Output:1 inch NPT female thread
Sample Temperature:0 to 50 °C (32 to 122 °F)
Weight:35.05 lbs. (15.9 kg)
Weight 2:40 lbs

Parameters

 